Unit of Shoulder and Elbow Surgery, D. Cervesi Hospital, Via L. V. Beethowen 46, Cattolica, Italy
*Corresponding author Emails: giovannimerolla@hotmail.com; giovanni.merolla@auslrn.net
Introduction
Osteoarthritis of the glenohumeral joint is a source of severe pain and disability. Furthermore, shoulder osteoarthritis is frequently associated with tear or atrophy of the rotator cuff that only gets worse over time. Shoulder arthroplasty gives satisfactory results, restoring shoulder function as well as improving patient’s quality of life. In this article, we have reviewed the biomechanics, surgical technique and results of anatomical and reverse shoulder arthroplasty.
Conclusion
Shoulder arthroplasty remains the gold standard treatment for advanced shoulder osteoarthritis of the glenohumeral joint. However, surgeons who intend to approach this type of surgery should be aware of the need for an accurate preoperative selection of both the patient and the type of implant and a thorough understanding of potential complications that may arise during implantation and postoperatively.
Degenerative osteoarthritis (OA) of glenohumeral joint is less common than that seen in weight-bearing joints, such as the hip and knee, but the incidence of OA increases with age and remains a source of severe pain and disability[1,2]. Furthermore, shoulder OA is frequently associated with tear or atrophy of the rotator cuff[3,4]. In patients with severe glenohumeral arthritis, shoulder arthroplasty gives satisfactory results, restoring shoulder function and improving patient’s quality of life. Charles Neer[5] first described the results after carrying out a humeral replacement, but a long-term evaluation showed that a cohort of patients continued to complain of pain and weakness after going through hemiarthroplasty. These complications were attributed to implant mobilization[6], glenoid erosion[7] and rotator cuff deficiency[8,9,10]. Consequently, a polyethylene glenoid component was introduced to reduce the risk of prostheses failure and related decline in patient’s quality of life[6]. In order to tackle the unsatisfactory outcomes of anatomical arthroplasty carried out for treating shoulder osteoarthritis with rotator cuff insufficiency, a new type of prosthesis was developed at the end of 1980, which is called the ‘reverse prostheses,’ the development of which was based on the assumption that the new design can increase the deltoid lever arm and improve shoulder function[11].
In this article, we have reviewed the biomechanics, surgical technique and results of anatomical and reverse shoulder arthroplasty (RSA).
Anatomical total shoulder arthroplasty (TSA) makes use of unconstrained monoblock (Figure 1) or modular (Figure 2) humeral components. Instead of the standard stem, the more recently developed modern implants come with a hydroxyapatite-coated ‘corolla’ impacted without cement in the humeral methaphysis (TESS[®]; Figure 3). An example of the last-generation humeral component is the ‘short stem’ with a prevalent metaphyseal grip (Figure 4). Head prostheses are available in several sizes, standard or with eccentric offset (Figure 1).
![]() |
Monoblock humeral stem with humeral head prostheses (Zimmer, Warsaw, IN, USA). |
![]() |
Humeral stem (A), humeral body (B), metal-backed glenoid component (C) and polyethylene liner of a modular humeral component (LIMA, San Daniele del Friuli, Italy). |
![]() |
Stemless shoulder prostheses: ‘corolla’ with hydroxyapatite coating and the polyethylene glenoid component for total shoulder replacement (TESS[®] Biomet, Warsaw, IN, USA). |
![]() |
Short stem with offset humeral head prostheses (Tornier SAS, Montbonnot Saint Martin, France). |
Glenoid prostheses include the following components:
Polyethylene components with keel or pegs (Figure 5) fixed on the cancellous bone with cement; pegged glenoids are also available with a flanged uncemented central peg to promote osseointegration
Standard metal-backed glenoid (Figure 2) fixed with screws and covered with a polyethylene liner
Trabecular tantalium-backed glenoid (TMT[®]; Figure 6) fixed on the bone under pressure[12].
![]() |
Keeled and pegged polyethylene glenoid component (Zimmer, Warsaw, IN, USA). |
![]() |
TMT[®] glenoid component (Zimmer, Warsaw, IN, USA). |
As for treating glenoid, a TMT[®] humeral component enabling the healing of humeral fractures is available[13].
A resurfacing design has been developed in several sizes with a short central head stem (cylindrical, fluted, tri-fin or threaded) and a metal-backed hydroxyapatite coating.
Reverse prosthesis is a semi-constrained, totally modular device (Figure 7). The glenoid component consists of a baseplate (metaglene), provided with a large central peg and secured to the native glenoid by cortical screws (2 or 4), which may be straight or angled. The glenosphere (a round metal ball approximately two-third of sphere) is fixed on the baseplate with a screw. It can be completely medialized or slightly lateralized, in order to prevent scapular neck erosion. The humeral component consists of a proximal cup-shaped portion and a metal stem press-fitted or cemented on the medullary canal. A radiolucent polyethylene insert sits on this cup portion and articulates with glenosphere. As for anatomical implants, reverse prostheses are available with a short stem having a predominantly metaphyseal grip.
![]() |
Reverse prostheses (Tornier SAS, Montbonnot Saint Martin, France). |
In order to obtain satisfactory results from shoulder replacement the following are required: (a) prosthetic reproduction of a normal bone morphology, (b) restoration of capsular tension and (c) restoration of stability and motor function in the muscle. The following geometric parameters are to be considered before performing shoulder arthroplasty:
> Neck inclination
> Humeral head diameter and height
> Humeral head retroversion
> Head offsets
> Distance between acromion and humeral
The cervicodiaphyseal angle[14] measures between 135° and 145°. Prostheses are usually designed with a fixed angle of 130° to 135° and the instrumentations perform head osteotomy at that angle. The diameter of humeral head[15] varies widely, from 38 to 58mm (median 46mm). Degenerative diseases alter the spherical shape; hence, often the prosthetic head diameter cannot be determined. The component’s diameter is thus chosen at the time of trial reduction based on the height of the hemisphere that has a broad, linear relationship with the head diameter. In all humeri, the superior edge of the head protrudes above the superior edge of the greater tuberosity by 2 to 5mm[16]. When the head component is positioned under the edge of the greater tuberosity, the joint’s instantaneous centre of rotation (COR) descends, resulting in reduced lowering of humeral head and increased tension in adduction, and signally, in early, painful subacromial impingement. On the other hand, a head protruding excessively above the greater tuberosity induces increased tension on the cuff (‘overstuffing’). The humeral head is retroverted with respect to the coronal plane. The angle of retroversion is subtended between the epicondylar axis and the central axis of the humeral head. Its median value is 20° and is proportional to the angle of retroversion of the scapula, which also varies widely (0°–60°). Small errors in head retroversion do not significantly alter the tension in neither the capsuloligamentous system nor the instantaneous COR; an excessive retroversion may induce posterior head subluxation in the case of a posterior cuff tear, whereas an insufficient retroversion may cause subscapularis impingement. The centre of the head does not lie on the diaphyseal humeral axis but appears displaced both in the coronal and the transverse planes. In the coronal axis, the offset ranges from 2 to 12 mm (median 7mm;
Humeral head resurfacing has to restore the normal humeral head geometry that is completely distorted by OA. Physiologically, the humeral head is retorverted and is inclined medially relative to the humeral shaft; therefore, these parameters and the head-shaft angle must be considered and restored when resurfacing is performed. If the radius of the humeral head curvature changes by 6mm, the shoulder range of motion (ROM) may decrease by 20° to 30° and this could affect the extent of glenohumeral translation during movement[18,19]. The resurfacing of humerus increases the humeral offset by 5mm (range 23–28 mm), but this should be balanced by the mean preoperative erosion at 6mm of the lateral offset[20].
The elements of reverse design, as initially described by Paul Grammont, include inherent prosthetic stability, convexity of glenoid component, glenosphere centre at or within the glenoid neck, and a medialized and distalized COR[11]. In the presence of rotator cuff insufficiency, reverse arthroplasty prevents humeral proximal migration because its congruent articulating surface achieves concentric motion. In fact, unlike total anatomical arthroplasty, which has a shallow glenoid component that cannot resist proximal migration and dislocation if the deltoid force vector is greater than 30° from the centreline, reverse arthroplasty has a non-anatomic neck-shaft angle of 155° and the resultant deltoid force vector can subtend at an angle of at least 45° from the centreline without risk of dislocation[21,22]. The medialization of COR at the prostheses–bone interface helps to avoid the problem of early loosening in the first reverse implants. Even though the medialization reduces shear force and increases compressive force, there is a negative consequence: humeral adduction causes inferior impingement, favouring the scapular neck erosion (‘scapular notching’)[23]. The location of COR affects the ROM in the shoulder and the deltoid lever arm[24]. With inferior baseplate positioning and COR medialized, the lever-arm length is doubled. As a consequence, the efficacy of the deltoid for abduction will double as well, but at the same time the deltoid excursion produces a lesser arc of motion[22]. For these reasons, most surgeons tend to position the glenosphere inferiorly and slightly laterally because it has been shown to maximize the free impingement arc of motion and increase ROM in abduction[25].
Conventional arthroplasty is indicated in patients with concentric shoulder OA[26] (Figure 8). In cases of arthritis with instability derived from the humeral head deficiency, the prosthetic humeral component can restore the full articular surface. Glenoid prostheses can restore the contour of arthritic glenoid, provided the bone beneath it ensures adequate support[21]. When shoulder OA is associated with instability caused by rotator cuff tears, conventional arthroplasty and rotator cuff repair may provide joint stability. Arthritis coupled with instability and excessive capsular laxity can be treated with anatomical arthroplasty, using a larger humeral head and capsular tightening[21]. Even in cases with cuff deficiency and upward migration of humeral head stabilized by an intact coracoacromial arch, using an efficient deltoid, humeral hemiarthroplasty may provide sufficient shoulder comfort and function[21]; this could be the most plausible option in young patients with high functional demand, a situation where reverse arthroplasty may not be successful. Conventional arthroplasty is not ideal to treat instability with unreconstructable soft-tissue or osseous deficiencies, such as severe posterior glenoid bone deficiency. Even in cases where the posterior capsule and the rotator cuff have been lost after trauma or previous surgery, conventional arthroplasty cannot restore posterior stability[21]. The mechanical criteria for RSA include having a functional deltoid and the ability to achieve stable glenoid baseplate fixation. The main indications for RSA are see in elderly patients (≤70 years) who present with shoulder pseudoparalysis from cuff tear arthropathy (CTA; Figure 9), massive cuff tear with arthritis and massive, irreparable cuff tear[27,28]. However, the poor results observed in some patients with unconstrained TSA persuaded most surgeons to extend the use of RSA also to inflammatory arthritis, static humeral instability, sequelae or posttraumatic arthritis in cases of non-union or severe malunion of the greater tuberosity, and repeating anatomical arthroplasty as many times as needed following failures[7,28].
![]() |
Concentric glenohumeral osteoarthritis. |
![]() |
Cuff tear arthropathy. |
Radiographic analysis in true anteroposterior (AP) view and axillary view is recommended to assess the glenohumeral space, acromion–humeral distance, calcium deposits or ossifications, the proximal humeral epiphysis and the size of diaphysis. The gold standard in proeperative bone evaluation is computed tomography (CT), which is especially useful in determining glenoid bone stock and morphology according to Walch
![]() |
Axial CT scan in severe glenohumeral osteoarthritis. Note the glenoid erosion and the posterior subluxation of humeral head. |
Operations are performed on the patient seated in the beach-chair position, using a deltopectoral or anterosuperior shoulder approach. We describe the common steps followed in deltopectoral approach, which is routinely used in our hospital’s Shoulder and Elbow Unit.
The skin is marked and a cut[29] is performed from the clavicle, down to and across the coracoid tip and continued in a straight line to the anterior border of deltoid insertion (Figure 11). The interval between the deltoid and pectoralis major muscle with the cephalic vein that is retracted laterally with the deltoid is identified. The long head of biceps in the bicipital groove is tenotomized and the lesser tuberosity with subscapularis tendon is osteotomized. The dissection proceeds superiorly, from the base of the coracoid to the subacromial space, anteriorly and inferiorly, and thereafter the degenerate capsule is carefully removed. Then the subacromial space is explored, in order to save the coraco-acromial ligament. A suture is passed on the medial margin of the supraspinatus tendon, in order to have a tendon mark in case the rotator interval needs to be closed, with the subscapularis muscle medially retracted to expose the joint. A manoeuvre is made to dislocate the humeral head, by a movement of the arm in adduction, extension and external rotation. At this stage, it is necessary to completely remove the inferior ‘goat beard’ osteophyte to obtain the complete exposure of humeral head. During humeral exposure, it is ideal to use a large retractor in the glenohumeral joint, a blunt Hohmann under the deltoid in the subacromial space and a small Hohmann at the inferior humeral neck, with the retractor kept in contact with the bone to maintain a safe distance from the axillary nerve.
![]() |
Deltopectoral incision from the tip of coracoid to the humeral insertion of deltoid. |
All osteophytes present along the anatomical neck are removed and the humeral head is perforated at its highest point, 1cm superior medial to bicipital groove (‘hinge point’). The medullary canal is accessed through a graduated driving, which is mounted on the mask for cutting. Osteotomy of the head is carried out exactly at the anatomical neck, at 30° of retroversion (Figure 12). The channel is dug with a hand drill, gradually increasing the diameter to create a recess wide enough to accommodate the implant. The trial stem is inserted, carefully observing the degree of retroversion. With the arm in neutral rotation, the Morse taper of the stem should be oriented towards the centre of the glenoid. After positioning the stem, the prosthetic head closest to the original humeral anatomy is chosen. The head is put on the chosen trial stem and the off-set is corrected by rotating the eccentric head, giving uniform coverage to the humeral neck without creating abnormal stresses on the rotator cuff. A reduction manoeuvre is performed cautiously and the stability and the ROM of the implant are assessed, which should not be less than 90° in internal rotation, 120° in elevation and 30° in external rotation. Then, the shoulder is redislocated and a pass to the glenoid phase is made.
![]() |
Position of guides to adjust humeral head osteotomy at 30° of retroversion. The cutting was performed along the anatomical neck. |
The limb is placed at 70° to 90° of abduction, in external rotation and in moderate flexion, to put a Fukuda retractor (or a curved retractor) on the glenoid to posteriorly and inferiorly subluxate the humeral head for the exposure of glenoid (Figure 13). The capsule and the labrum are removed at 360°, the orientation of the glenoid surface is defined, a centre hole is drilled with a reamer in order to expose the subchondral bone for an effective bone–prostheses bond. The reaming is a crucial step to correct the orientation of glenoid defects, but we need not remove an excessive amount of subchondral bone to avoid the weakening of glenoid bone if it has a higher risk of fractures. At this point, with the use of guides and appropriate forms, three or four holes (Figure 13) are made to accommodate the trial component and the intrinsic instability is tested. After verifying the final size of the glenoid component, a generous washing is made and, using a 60-ml pressurized syringe, cement is injected into cuts for pegs. The cement is impacted with dedicated instruments, and on the neck surface of the component, and manual re-drilling of holes is carried out using the syringe. The final glenoid prosthesis is then impacted (Figure 14). When polyethylene[29] component is used with cementless central peg, the flanged fluted peg is embedded within the morselized bone in the glenoid central hole.
![]() |
Cemented all-polyethylene glenoid prostheses after the impaction with cement (Zimmer, Warsaw, IN, USA). |
The centre of the glenoid tracing two orthogonal lines along the longitudinal and transversal axes is identified with an electric cautery, and then a K wire is inserted (15-cm long, 2.5-mm diameter) at least 25 mm into the bone, orthogonal to the glenoid surface and slightly off the centre. The glenoid reamer is used to remove the glenoid cartilage, exposing the subchondral bone. The glenoid drilling is continued until the peg reaches the end; in case a larger peg is used, the glenoid drill may be used to widen the hole. After choosing the correct size of the M-B cementless component, it is pushed into the central hole with a handle positioner, ensuring that the major axis of the implant coincides with the largest axis of glenoid. Screws are then inserted and fitted within 30°. Finally, using the thumb, the polyethylene liner pushing is inserted (Figure 15 A–E).
TMT[®] glenoid without screw fixation can be used to optimize the bone ingrowth and reduce the risk of glenoid failure[29].
Before the implantation of final humeral component, the trial head is put again and the shoulder is lowered. The tension of soft parts, size, offset of head and the new articular relationship between the glenoid prostheses implanted and the ROM are all checked; subscapularis is returned to its bone insertion on the lesser tuberosity to assess the degree of tension. After assessing these parameters, the humeral trial is removed and four or five bone sutures are passed (flexidene #4) on the neck of the humerus to fix the subscapularis. In case cemented humeral prostheses are chosen, the plug is inserted into the canal and dried in order to perform an accurate lavage. The cement is injected under pressure and the final stem is introduced with the correct version as previously measured. Some time must be allowed for the cement to consolidate. The trial head is inserted again to check the offset and the tension of the subscapularis, the rotator cuff and the ROM. The trial is then removed and the final head prostheses are implanted, ensuring that the offset previously assessed is accurately reproduced. Shoulder is reduced, close the rotator interval to its base with reabsorbable suture (ethibond #2) and the subscapularis is fixed using a modified Mason–Allen stitches. Anterior and posterior drawer manoeuvres[29] are repeated to assess the stability of prostheses and evaluate the mobility achieved; the area is washed, and the status of axillary nerve is checked in order to place a subdeltoid drainage. Afterwards, both deep and surface layers are placed, the arm is placed in a sling and the patient is sent for postoperative X-ray control.
Humeral head replacement is exposed as previously explained. The centre of the head is located using a k wire as the guide, and a fully cannulated instrument is used to restore the humeral head shape and contour to allow a close fit of the final implant. The central hole is drilled for tapering the docking peg, the trial head is placed to ascertain the correct size and the resurfacing head is fixed, which has a Ti (plasma spray hydroxyapatite coating) on their underside. This aids fast osteointegration and corrects any instability (Figure 16). Glenoid can be replaced using a polyethylene component to obtain a total resurfacing arthroplasty.
![]() |
Resurfacing humeral head (LIMA Corporate, San Daniele del Friuli, Italy). |
The stemless humeral prostheses represent the most modern choice in third-generation shoulder implants, which help avoid stem-related complications typical with shoulder implants[31,32,33]. A stable fixation is achieved using an ingrowth metaphyseal ‘corolla’ pressed in the cancellous bone of humeral neck. After a complete exposure of proximal humerus, all osteophytes are removed to determine the head size, the head is cut at the level of anatomical neck, a template is placed on the humerus to choose the size of corolla, a pin is drilled through the centre of the humeral template and then the template is removed. A puncher is impacted over the guide pin that is removed later and a trial head is placed on the punch, performing dynamic manoeuvres to evaluate the height, stability and size of the final implant. In case of glenoid arthritis, a cemented polyethylene component can be implanted in a standard fashion. Short humeral stems have been recently[31] introduced as an alternative to the standard stem and stemless humeral component. A successful placement requires implantation in the neutral position, in order to gain appropriate fixation in the proximal diaphyseal shaft.
The shoulder is exposed using the deltopectoral approach previously described. The centromedullary humeral cutting guide is placed at the top of humeral head and set with 20° of retroversion. The humeral head osteotomy should incline at 155° and should be minimal, which provides correct tension and minimizes risks of instability. A trial humeral prosthesis is inserted to protect the humeral epiphysis when the humerus is posteriorly subluxate with a curved retractor. The glenoid is prepared by removing the labrum and the capsule all around, assessing for any wear and loss of bone stock. A major wear of the glenoid may require additional bone graft from the humeral head. The entry point of the drill guide is prepared and the direction of the central peg in the baseplate is determined. At this stage, it is necessary to avoid any upward pressure on the proximal humerus, as the same can lead to the implanting of metaglene with a superior tilt or to the drilling of centre hole at a very high location, which can then lead to impingement of the humerus in adduction. The optimal position of glenoid should be with a slightly inferior tilt, with the glenosphere overlapping the inferior glenoid rim. Then the baseplate (metaglene) is secured with two or four screws and the glenosphere is attached to the metaglene with a screw (Figure 17). Once the glenoid is in place, the humerus is located, and the canal is drilled to choose the appropriate size of the stem that is cuffed with a trial insert (Figure 18). The implant is reduced and the stability of prostheses is tested, determining the insert’s thickness by stability in adduction and by assessing the tension of both the conjoined tendon and the lateral deltoid. A 6-mm insert is most commonly[34] used. The trial is then removed and the final cemented or press-fit component is implanted. The subscapularis is reattached to bone sutures and the wound is closed in layer.
![]() |
Reverse arthroplasty: baseplate (metaglene) fixed with screws (Tornier SAS, Montbonnot Saint Martin, France). |
![]() |
Reverse arthroplasty: humeral component with the proximal cup-shaped portion and polyethylene insert. |
A radiographic analysis of shoulder arthroplasty should be carried out, including the AP and axillary views; for reverse arthroplasty, an additional ‘Y’ view is recommended.
A proper AP assessment includes the following parameters in TSA[35]:
> Orientation of the humeral component
> Translation of the humeral component
> Offset of the humeral head
> Size and height of the humeral head
> Distance between the acromion and–the humeral
> Distribution and fixation of the cement
> Stress shielding and cortical resorption
> Radiolucent lines
> Subsidence and tilt
Figures 19, 20 and 21 show postoperative X-rays of TSA with different glenoid components, and Figure 22 is an X-ray of humeral resurfacing.
![]() |
Postoperative X-rays: stemless shoulder prostheses (TESS[®]) with cemented polyethylene glenoid component. |
![]() |
Total shoulder arthroplasty (TSA) with uncemented stem and metal-backed glenoid component. |
![]() |
Total shoulder arthroplasty (TSA) with TMT[®] glenoid component. |
![]() |
Humeral resurfacing. |
Axillary view is specifically used to assess glenoid erosion and prostheses instability[36].
The region and the features to examine in reverse arthroplasty are as follows[37] (Figure 23):
> Glenosphere components’ alignment and stability; if there is a dislocation, is it anterior or posterior?
> Position of metaglene relative to the native glenoid
> Are metaglene anchoring screws within the glen?
> Position and anchoring of metaglene screws within the scapula
> Radiolucency at the component–bone or cement–bone interface
> A complete analysis of all components in the prosthesis
> Erosion of the inferior border of scapula
> Heterotopic ossification
> Are supporting bones intact?
![]() |
Reverse arthroplasty. |
The author has referenced some of his own studies in this review. These referenced studies have been conducted in accordance with the Declaration of Helsinki (1964), and the protocols of these studies have been approved by the relevant ethics committees related to the institution in which they were performed. All human subjects in these referenced studies gave informed consent to participate.
Anatomical shoulder arthroplasty provides good results for pain reduction and recovery of shoulder function[26,35], but several authors showed better clinical outcomes with total arthroplasty than with humeral hemiarthroplasty[38,39,40]. Although HSA is advantageous in select cases of osteonecrosis and eccentric OA[39], it is not ideal for treating severe shoulder OA and the associated the risk of glenoid erosion[41]. Furthermore, another weak point in TSA is the loosening of glenoid component[41,42,43]. However, humeral loosening is uncommon[32,33]. Cemented polyethylene glenoid’s failure leads to unsatisfactory results after TSA[42], including the following types of failures: (a)
Glenoid reaming and fixation technique require adequate seating and stability of glenoid prosthesis, which may be affected by bone-surface changes induced by reaming[43]. Furthermore, sometimes the glenoid could be not seated properly because of the incomplete removal of glenoid osteophytes. Cementing can be performed either manually or with a syringe; in this regard, micro-CT scans demonstrated that using a syringe achieved 100% circumferential fixation of pegs and the circumferential fixation achieved is only 53% if pegs are inserted manually by using finger pressure[43]. These findings prompted us to adopt syringe pressurization for glenoid implantation. Glenoid component fixation may get affected by glenoid mineralization patterns that have been shown to be heterogeneous, particularly when there is a linear relationship between bone mineral density and strength distribution. The most common patterns of mineralizations found were typically bicentric, with the highest values detected in squares 4 and 6 of anterior and posterior glenoid[44]. For these reasons, we suggest that an accurate preoperative CT analysis be performed to measure bone loss and that bone graft be considered for osseointegration in the case of severe glenoid erosion.
Partially cemented glenoid prostheses with a flanged central peg have been advocated, given their capacity to work well in osseointegration. During this surgical procedure, the central peg remains uncemented and the flangs are completely embedded into bleeding cancellous bone (‘morselized bone graft’)[45]. Although recent studies[45,46] and our CT findings (unpublished data) showed a good bone mantle around the central uncemented peg, the follow-up period proved too short to confirm that bone osseointegration is indeed complete.
Surgical procedure for metal-back glenoid requires a central press-fit and fixation with two screws that provides for a rigid system with polyethylene liner around the surface. A flat metal-back flash with glenoid ensures prostheses stability but involves the risk of bone resorption around the metallic baseplates and screws[47]. Furthermore, polyethylene wear can induce metal-on-metal contact with associated synovitis.
Boileau
In order to reduce the risk of glenoid erosion, Merolla
RSA guarantees good results in CTA and massive irreparable rotator cuff tears[59,60,61,62,63,64] and higher patient satisfaction when painful pseudoparalysis is the principle indication[27]. In patients with CTA, over a follow-up period ranging from 8 to 24months, the mean active external rotation was between 7° and 14°[65,66,67], which shows a large variation, from -44° to +60°[66]; pain was also significantly reduced[65,66,67]. Final median internal rotation reached L3[66,67] but again showed large variation from the greater trochanter to T12[65]. These clinical results confirm that most patients had functional reach but rotation still remains a concern.
The survivorship of RSA at 10 years was 89% (95% confidence interval: 83–96), but it was found that there was a gradual decline in Constant–Murley score (CS); when the CS was < 30 points, the rate of survival at 10 years fell to 72%[68]. The age is another risk factor when performing RSA; therefore, most surgeons prefer RSA as a treatment option only for patients aged above 65 years and have low demands[21]. For patients aged between 70 and 73 years who present with irreparable massive rotator cuff tears, at a mean follow-up of 24months, outcome scores improved and ROM was similar compared to that observed in patients with cuff-tear arthropathy[69].
Furthermore, there was no significant difference between the outcome related to patients who had undergone previous rotator cuff surgery and those who had not[69]. It was interesting to note that patients who had < 90° of active forward flexion prior to surgery had a significantly better ROM and functional outcome and higher patient satisfaction than those who had > 90° forward flexion prior to surgery[69,70]. The outcome of the treatment of fracture sequelae with RSA is equivalent to that of CTA. The most frequent complication of RSA is the scapular notching[60,64,72,73,74,75], followed by the loosening of glenoid component, infections, instability and other complications associated with humeral component[71]. Notching is identified on X-ray as a resorption or wear of the lateral pillar of the scapula, medially and progressively superior to the inferior aspect of glenoid baseplate as described in the Nerot classification[76]. Scapular notching can induce partial destruction of the inferior aspect of glenoid, but its clinical relevance is a point of debate; in fact, some authors[77] reported poor clinical outcomes associated with notching and some[78] considered the phenomenon altogether clinically irrelevant. Nyffeler
Shoulder arthroplasty remains the gold standard treatment for advanced shoulder OA of the glenohumeral joint, but surgeons who intend to approach this type of surgery should be aware of the need for an accurate preoperative selection of the patient and the type of implant as well as potential complications that may arise over time.
All authors contributed to the concept on, design, and preparation on of the manuscript, as well as read and approved the final manuscript.
None declared.
None declared.
All authors abide by the Association on for Medical Ethics (AME) ethical rules of disclosure.